home *** CD-ROM | disk | FTP | other *** search
/ Shareware Overload Trio 2 / Shareware Overload Trio Volume 2 (Chestnut CD-ROM).ISO / dir26 / med9410o.zip / M94A2711.TXT < prev    next >
Text File  |  1994-10-25  |  3KB  |  40 lines

  1.        Document 2711
  2.  DOCN  M94A2711
  3.  TI    Evaluation of Vironostika HIV Uni-Form II EIA, a third generation assay.
  4.  DT    9412
  5.  AU    Vercauteren G; Mangelschois M; van der Groen G; Institute of Tropical
  6.        Medicine, Department Infection & Immunity,; Antwerpen, Belgium.
  7.  SO    Int Conf AIDS. 1994 Aug 7-12;10(1):242 (abstract no. PB0397). Unique
  8.        Identifier : AIDSLINE ICA10/94369864
  9.  AB    OBJECTIVE: To evaluate the performance of a new third generation enzyme
  10.        immunoassay (EIA). METHODS: A panel of 412 aliquoted samples stored at
  11.        -20 degrees C including samples of African (14%), European (76%) and
  12.        other or unknown origin (10%) was tested on the Vironostika HIV Uni-Form
  13.        II EIA (Organon Teknika Boxtel, The Netherlands). The prevalence for
  14.        HIV-1 and HIV-2 antibody in this panel was 10.4% and 2.2% respectively.
  15.        Additionally 4 HIV-1 seroconversion panels (PRB914, PRB916, PRB917,
  16.        PRB918) from BBI were tested. These results were compared with 8
  17.        different EIA's currently used in Europe. RESULTS: All known HIV-1 (43)
  18.        and HIV-2 (9) positive samples were detected with the EIA evaluated.
  19.        Five sera (5/359) remained repeatedly false reactive. These samples
  20.        belonged to patients with a history of malaria (2) an elevated
  21.        triglyceride (2) and with cystes of Entamoeba coli (1). The specificity
  22.        for this panel was 98.6%, however the results obtained on fresh taken
  23.        and frozen routine samples in Belgium (n = 120) (data not shown) gave a
  24.        specificity of 100%. The Vironostika HIV-Uni-Form II EIA performed
  25.        significantly better on the early seroconversion panels than the
  26.        Vironostika HIV mixt EIA, and equally well compared to the Abbott
  27.        recombinant 3rd generation EIA HIV-1+2. CONCLUSIONS: In this evaluation
  28.        using frozen serum samples, the sensitivity of the Vironostika HIV
  29.        Uni-Form II assay was 100% and the specificity 98.6%. HIV antibodies
  30.        were detected as early with the HIV Uni-Form II EIA as with the Abbott
  31.        HIV-1+2 EIA 3rd generation for the early seroconversion panels tested.
  32.  DE    AIDS Serodiagnosis/*INSTRUMENTATION  Comparative Study  Human  HIV
  33.        Seropositivity/*DIAGNOSIS/IMMUNOLOGY  HIV-1/*IMMUNOLOGY
  34.        HIV-2/*IMMUNOLOGY  Immunoenzyme Techniques/*INSTRUMENTATION  Predictive